OMT air/oil heat exchangers have been designed
to be used on the return line of the hydraulic
systems.
The special structure of the cooler element in aluminium alloy
increases the conductivity quality, and the
brase welding process of the conduits allows a
high thermic exchange and a good resistance to
pressure, obtained by using qualified materials.
Radiating Mass Data
Material Aluminium
Nominal pressure 25 bar
Test pressure 35 bar
Max temperature 120°C
|
Fluid Compatibility
Mineral oils, hl, hlp, water-oil emulsion.
Installation We recommend to install a by-pass valve in parallel to the
heat exchanger, for its protection during the starting up.
Make sure there is no obstacle to the air flow.
MATERIALS Fan Steel
or hard plastic
Fan case Steel
Fan protection Steel or hard plastic
|

|